If , defrost terminates if the duration ( F05 ) ends OR if the defrost sensor reads a temperature equal to or higher than the termination limit ( F06 ). 3. Fan Operating Modes ( F09 )
Press once on the desired code to view its current value. Press ▲ or ▼ to adjust the value to your requirement. Stc-600 Temperature Controller Manual Pdf
: Triggered when the ambient sensor detects temperatures exceeding the upper limit of +99°C.
: Introduces a defensive delay period (measured in minutes) before restarting the compressor. This variable protects the motor from rapid short-cycling. : If , defrost terminates if the duration
| Code | Parameter Name | Default Setting | Recommended Range | | :--- | :--- | :--- | :--- | | | Temperature Set Point (SV) | 25°C | Your target temp | | F2 | Differential / Hysteresis (HY) | 2.0°C | 0.5°C - 5.0°C | | F3 | Cooling Delay Protection (PT) | 3 Minutes | 0-10 min (3 min saves compressor) | | F4 | Temperature Calibration (CA) | 0.0°C | ±5°C | | F5 | Unit Selection (CF) | 0 = Celsius | 1 = Fahrenheit | | F6 | High Temperature Alarm (AH) | 99°C | Set above your max desired temp | | F7 | Low Temperature Alarm (AL) | -40°C | Set below your min desired temp |
: Three-digit LED with status indicators for refrigeration, defrosting, and fan activity. Core Features & Modes Press ▲ or ▼ to adjust the value to your requirement
The STC-600 temperature controller manual PDF is a comprehensive guide that provides users with detailed information on the device's features, installation, operation, and maintenance. By following the instructions and guidelines outlined in the manual, users can ensure optimal performance, accuracy, and reliability. Whether you are a new user or an experienced professional, this article aims to provide you with a thorough understanding of the STC-600 temperature controller manual PDF.
The cooling relay turns when: Storage Temperature ≥ F01 + F02 (provided the compressor delay time F03 has elapsed).
Defrost output relay. Connects to the defrost heating elements or hot gas valve. Terminals 7 & 8: Evaporator fan control relay. Terminals 9 & 10: Storage room temperature sensor (NTC).