When intermittent faults occur (such as a random E-stop drop out), standard monitoring is too slow to catch the culprit signal. Navigate to the menu and select Signal Trace . Define your Trigger Condition (e.g., when X0.0 turns OFF). Select the target addresses you want to monitor.
Allows multi-window schematic drafting of relay-style contacts and coils. Function Block (FB) Support:
Newer FANUC hardware supports "Function Blocks" (FB) that allow for modular programming. Version 9.5 is required to unlock and edit these advanced structures.
Locating a specific I/O signal (like an emergency stop X address or a diagnostic G address) is significantly faster. The cross-reference tool instantly builds an interactive list of every instance an address is read or written throughout the entire project structure. Step-by-Step Programming Workflow
Force bits (with caution) to test solenoids and relays without needing to trigger the entire machine cycle. Conclusion
On the CNC, set the IP address via the SYSTEM > PMC > ONLINE settings.